07 December 2023>: Articles
Immune-Mediated Non-Infectious Periaortitis After Aortic Graft Replacement Surgery: A Case Report Highlighting the Need for Immunosuppressive Therapy
Unusual clinical course, Challenging differential diagnosis, Unusual setting of medical care
Yuki Hiramatsu A , Eiji Hiraoka A* , Hikaru Ito A , Keiichi Iwanami A , Joji Ito A , Minoru Tabata ADOI: 10.12659/AJCR.941428
Am J Case Rep 2023; 24:e941428
Figure 4. Contrast-enhanced computed tomography at the onset of stroke 6 months after the first surgery. (A) Aortic root just above implanted aortic valve (Gelweave Valsalva™). Contrast was leaked into pseudoaneurysm. Thrombus was noted in the pseudoaneurysm. (B) Ascending aortic graft: Triplex™. Contrast was leaked into the pseudoaneurysm.