28 June 2012
Time-resolved imaging of contrast kinetics does not improve performance of follow-up MRA of embolized intracranial aneurysms
Zbigniew SerafinABCDEF, Piotr StrześniewskiBDE, Władysław LasekEFG, Wojciech BeuthBEFDOI: 10.12659/MSM.883199
Med Sci Monit 2012; 18(7): MT60-65
Abstract
Background: The use of contrast media and the time-resolved imaging of contrast kinetics (TRICKS) technique have some theoretical advantages over time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. We prospectively compared the diagnostic performance of TRICKS and TOF-MRA with digital subtracted angiography (DSA) in the assessment of occlusion of embolized aneurysms.
Material/Methods: Seventy-two consecutive patients with 72 aneurysms were examined 3 months after embolization. Test characteristics of TOF-MRA and TRICKS were calculated for the detection of residual flow. The results of quantification of flow were compared with weighted kappa. Intraobserver and interobserver reproducibility was determined.
Results: The sensitivity of TOF-MRA was 85% (95% CI, 65–96%) and of TRICKS, 89% (95% CI, 70–97%). The specificity of both methods was 91% (95% CI, 79–98%). The accuracy of the flow quantification ranged from 0.76 (TOF-MRA) to 0.83 (TRICKS). There was no significant difference between the methods in the area under the ROC curve regarding both the detection and the quantification of flow. Intraobserver reproducibility was very good with both techniques (kappa, 0.86–0.89). The interobserver reproducibility was moderate for TOF-MRA and very good for TRICKS (kappa, 0.74–0.80).
Conclusions: In this study, TOF-MRA and TRICKS presented similar diagnostic performance; therefore, the use of time-resolved contrast-enhanced MRA is not justified in the follow-up of embolized aneurysms.
Keywords: Kinetics, Intracranial Aneurysm - therapy, Imaging, Three-Dimensional - methods, Follow-Up Studies, Embolization, Therapeutic, Contrast Media - diagnostic use, Carotid Artery, Internal - radiography, Magnetic Resonance Angiography - standards, Time Factors
Editorial
01 March 2024 : Editorial
Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and Transfusion-Dependent β-ThalassemiaDOI: 10.12659/MSM.944204
Med Sci Monit 2024; 30:e944204
In Press
21 Feb 2024 : Clinical Research
Potential Value of HSP90α in Prognosis of Triple-Negative Breast CancerMed Sci Monit In Press; DOI: 10.12659/MSM.943049
22 Feb 2024 : Review article
Differentiation of Native Vertebral Osteomyelitis: A Comprehensive Review of Imaging Techniques and Future ...Med Sci Monit In Press; DOI: 10.12659/MSM.943168
23 Feb 2024 : Clinical Research
A Study of 60 Patients with Low Back Pain to Compare Outcomes Following Magnetotherapy, Ultrasound, Laser, ...Med Sci Monit In Press; DOI: 10.12659/MSM.943732
26 Feb 2024 : Clinical Research
Predictive Value of Combined HbA1c and Neutrophil-to-Lymphocyte Ratio for Diabetic Peripheral Neuropathy in...Med Sci Monit In Press; DOI: 10.12659/MSM.942509
Most Viewed Current Articles
17 Jan 2024 : Review article
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
16 May 2023 : Clinical Research
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
14 Dec 2022 : Clinical Research
Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase LevelsDOI :10.12659/MSM.937990
Med Sci Monit 2022; 28:e937990
01 Jan 2022 : Editorial
Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...DOI :10.12659/MSM.935952
Med Sci Monit 2022; 28:e935952