A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation

Unusual or unexpected effect of treatment, Diagnostic / therapeutic accidents, Rare disease

Janine Sarach ABEF , Irin Zschokke ABEF , Gian A. Melcher AE

DOI: 10.12659/AJCR.895486

Am J Case Rep 2015; 16:904-907

0 Comments

Abstract

BACKGROUND: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava.

CASE REPORT: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection.

CONCLUSIONS: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to date. This case highlights the importance of awareness of possible, rare, life-threatening complications during port implantation, mostly performed in multimorbid patients by surgeons in training.

Keywords: Angiography, Catheterization, Central Venous - instrumentation, Central Venous Catheters - adverse effects, Fluoroscopy, Hematoma - etiology, Mediastinum - blood supply, Phlebography, Subclavian Vein, Tomography, X-Ray Computed

Background

Central venous access is a common procedure with 3 main complication groups: mechanical, infectious, and thrombotic. Prior studies have demonstrated rates of mechanical complications, such as arterial puncture, improper positioning, pneumothorax, hematoma or hemothorax, in 5% to 19% of catheter attempts [1–3]. Infectious complications occur in 5% to 26% of catheter attempts and thrombotic complications in 2% to 26% [1].

Risk factors for mechanical complications can be patient-associated or surgeon-associated [1,2,4]. The rate of life-threatening complications reported in the literature is 6.2–10.7% [2,5].

Another example of intrathoracic hematoma due to a mechanical complication is esophageal perforation after introducing a nasogastric tube [6].

In this paper we present a rare but life-threatening complication of central venous catheterization due to perforation of the superior vena cava using Seldinger’s technique.

Case Report

A 68-year-old female patient with primary peritoneal adenocarcinoma of serous-papillary type 1 (pT3c, pN1 (1/26), G3) was admitted to our hospital for an elective Chemo-Port placement. Six weeks before admission, she underwent tumor debulking with bilateral adnexectomy, omentectomy, and resection of pelvic and paraaortic lymph nodes. A vaginal hysterectomy had been performed in 1983 because of uterine prolapse.

Medical history contained one-vessel coronary artery disease treated with bypass surgery. An aneurysm of the aorta also led to a supracoronary ascending aorta replacement with a biological aortic valve. Other comorbidities included atrial fibrillation and arterial hypertension. The patient was receiving antiplatelet treatment with acetylsalicylic acid. The preoperative laboratory parameters were normal.

In our institution, port implantation exposing the cephalic vein is usually performed under local anesthesia. In this particular case, we found a very small, collapsed right cephalic vein. Therefore, we decided to place the catheter over the right subclavian vein using Seldinger’s technique. Two unsuccessful attempts and the patient’s considerable agitation led to an endotracheal intubation. This action was followed by temporarily but severe hemodynamic instability. After stabilizing the patient, the port catheter was finally placed into the superior vena cava applying Seldinger’s technique. Since blood aspiration was not possible to perform, fluoroscopy was used, showing mediastinal contrast extravasation without contrasting the venous system (Figure 1A, 1B).

After explantation of this catheter and a successful repuncture of the right subclavian vein, a new port system was finally placed in the correct position and without any contrast extravasation.

Following extubation, the patient presented severe respiratory distress. Consecutive cardiopulmonary resuscitation and re-intubation were necessary. Clinically, she had reduced breath sounds and a hyper-sonorous percussion on the right side was heard. We presumed a pneumothorax; therefore, a thoracic drain was inserted.

The patient was transferred to the intensive care unit. The CT scan (Figure 2) showed a significant hematoma in the lower neck and posterior mediastinum, with tracheal compression.

Additionally, a small residual pneumothorax on the right side and large bilateral pleural effusions were revealed, but active bleeding was not detected.

On the 6th postoperative day, a dilated tracheotomy was performed to ease ventilation.

A few days later, as the infection parameters increased, the patient still needed catecholamines and intensive care. No infection could be detected in the CT scans of the neck, thorax, and abdomen. The mediastinal hematoma seemed stable.

Because of low oxygen saturation and growing pleural effusion, the right pleura was punctured and antibiotics were adjusted. Nevertheless the patient remained febrile and infection parameters remained. With repeatedly positive blood cultures and after excluding endocarditis by transesophageal echocardiography, an infected port system was suspected. The port system was removed on the 16th postoperative day and analysis revealed colonization with Enterococcus faecium.

Thereupon, the patient recovered and was finally discharged to a rehabilitation clinic.

Discussion

Numerous complications are associated with central venous catheterizations. Complications can be divided into three groups: mechanical, infectious and thrombotic [1].

Patient-associated risk factors for mechanical complications are advanced age, gender, low or high body mass index, prior catheterization, surgery, or radiotherapy, and puncture site.

Surgeon-associated risk factors are the number of venous punctures, the time needed for placing the catheter, surgeon experience [1,2,4]. Higher success rates and lower rates of mechanical complications are clearly related to surgeon experience [7–9]. Using ultrasound guidance for catheter placement is still controversial.

Our patient was admitted for an elective Chemo-Port implantation. The procedure was performed by an experienced surgeon. The patient had a normal body mass index of 20.8 kg/m2, and no prior operations or radiotherapy had been performed in the operation field. A possible risk factor for perforation was a previous central venous catheterization in the right subclavian vein 6 weeks before, during the tumor debulking surgery. We could not find any further surgeon- or patient-related risk factors.

Mediastinal hematoma, as an example of a mechanical complication after central venous catheterization, has only been described a few times in the literature to date [5,10–16]. It is a rare but life-threatening complication of central venous catheterization using Seldinger’s technique. Perforation occurs generally during central venous catheterization in critical care. The perforation site is usually localized in the jugular or subclavian vein, and less often at the junction with the superior vena cava.

In this case, fluoroscopy revealed an extravasation in projection on the mediastinum. We assume that the perforation of the superior vena cava occurred while inserting the guidewire. An active hemorrhage was excluded by a CT scan, so we decided to use conservative treatment.

Retrospectively, it would have probably been wiser to interrupt the operation after detecting the mediastinal extravasation in order to first stabilize the patient. In doing so, some complications such as the pneumothorax and/or the postoperative catheter infection might have been avoided.

Conclusions

Chemo-Port implantation is a surgical procedure mostly performed in multimorbid patients by surgeons in training. Meticulous surgical technique, patient history, local particularities of the operation site, and knowledge of potential complications are extremely important. Close monitoring of the patient can provide life-saving information.

This case highlights the importance of awareness of potentially life-threatening complications during port implantation.

References:

1.. Eisen LA, Narasinham M, Berger JS, Mechanical complications of central venous catheters: J Intensive Care Med, 2006; 21; 40-46, pmid: 16698743

2.. McGee DC, Gould MK, Preventing complications of central venous catheterization: N Engl J Med, 2003; 348; 1123-33, pmid: 12646670

3.. Raad I, Intravascular catheter-related infections: Lancet, 1998; 351(9106); 893-98, pmid: 9525387

4.. Lefrant J, Muller L, De La Coussaye , Risk factors and immediate complication of subclavian vein catheterization in critically ill patients: Intensive Care Med, 2002; 28; 1036-41, pmid: 12185422

5.. Biswas S, Sidani M, Abrol S, Emergent sternotomy for mediastinal hematoma: A rare complication following internal jugular vein catheterization for chemoport insertion – a case report and review of relevant literature: Case Rep Anesthesiol, 2014; 2014; 190172, pmid: 24592335

6.. Arda I, Deniz F, Kemal P, A case report of esophageal perforation: Complication of nasogastric tube placement: Am J Case Rep, 2014; 15; 168-71, pmid: 24803977

7.. Sznajder JI, Zveibil FR, Bitterman H, Central vein catheterization – failure and complication rates by three percutaneous approaches: Arch Intern Med, 1986; 146; 259-61, pmid: 3947185

8.. Arrighi DA, Farnell MB, Mucha P, Prospective, randomized trial of rapid venous access for patients in hypovolemic shock: Ann Emerg Med, 1989; 18; 927-30, pmid: 2669571

9.. Merrer J, De Jonghe B, Golliot F, Complications of femoral and subclavian venous catheterization in critically ill patients: A randomized controlled trial: JAMA, 2001; 286; 700-7, pmid: 11495620

10.. shraf O, Sharif H, Life threatening mediastinal hematoma: a complication of central venous catheterization: J Pak Med Assoc, 2006; 56; 141-43, pmid: 16696518

11.. Masud T, Tapson JS, Mediastinal hematoma caused by subclavian catheterisation for haemodialysis: Int J Artif Organs, 1989; 12; 708-10, pmid: 2599670

12.. Tamura K, Park JJ, Unusual complications of central venous catheterization in thrombocytopenic patient: Eur J Radiol, 1985; 5; 154-55, pmid: 3858100

13.. Hohlrieder M, Oberhammer R, Lorenz IH, Life-threatening mediastinal hematoma caused by extra-vascular infusion through a triple-lumen cen-tral venous catheter: Anesth Analg, 2004; 99; 31-35, pmid: 15281497

14.. Szu-Chia C, Chuan-Sheng W, Shu-Hui C, Mediastinal hematoma caused by central venous catheterization: A rare couse of obscure blood loss: Kaohsiung J Med Sci, 2009; 25; 460-64, pmid: 19605342

15.. Saptarshi B, Marwa S, Sunil A, Emergent median sternotomy for mediastinal hematoma: a rare complication following internal jugular vein catheterization for chemoport insertion – a case repost and review of relevant literature: Case Rep Anesthesiol, 2014; 2014; 190172, pmid: 24592335

16.. Gupta P, Guleria S, Sharma S, Mediastinal haematoma: a rare complication following insertion of central venous catheter: Indian J Chest Dis Allied Sci, 2011; 53; 225-28, pmid: 22128622

In Press

Case report  China

Thrombolytic Therapy After Return of Spontaneous Circulation in Patients With STEMI From Medically Underdev...

Am J Case Rep In Press; DOI: 10.12659/AJCR.949976  

Case report  Greece

Multilevel Laminectomy for Lumbar Spinal Stenosis With Low Back Pain in Achondroplasia: A Case Report

Am J Case Rep In Press; DOI: 10.12659/AJCR.950290  

Case report  Italy

Fractional CO₂ Laser (SCAR3 Scanner) for a Hypertrophic Retracting Cleft Lip Scar: A Case Report

Am J Case Rep In Press; DOI: 10.12659/AJCR.950607  

Case report  Saudi Arabia

Postoperative Corneal Dellen Following PreserFlo MicroShunt: A Case Report

Am J Case Rep In Press; DOI: 10.12659/AJCR.950985  

Most Viewed Current Articles

07 Dec 2021 : Case report  USA 17,691,734

Edwardsiella tarda: A Classic Presentation of a Rare Fatal Infection, with Possible New Background Risk Fac...

DOI :10.12659/AJCR.934347

Am J Case Rep 2021; 22:e934347

06 Dec 2021 : Case report  Brazil 164,491

Lipedema Can Be Treated Non-Surgically: A Report of 5 Cases

DOI :10.12659/AJCR.934406

Am J Case Rep 2021; 22:e934406

21 Jun 2024 : Case report  China (mainland) 113,090

Intracranial Parasitic Fetus in a Living Infant: A Case Study with Surgical Intervention and Prognosis Anal...

DOI :10.12659/AJCR.944371

Am J Case Rep 2024; 25:e944371

0:00

07 Mar 2024 : Case report  USA 59,175

Neurocysticercosis Presenting as Migraine in the United States

DOI :10.12659/AJCR.943133

Am J Case Rep 2024; 25:e943133

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

American Journal of Case Reports eISSN: 1941-5923
American Journal of Case Reports eISSN: 1941-5923