Unusual Venous Access for Device Implantation

Unusual clinical course, Unusual setting of medical care

Mohammed Al-Sadawi BCDEF 1, Adam S. Budzikowski ABCDEF 2*

DOI: 10.12659/AJCR.916576

Am J Case Rep 2019; 20:1482-1486

0 Comments

Abstract

BACKGROUND: Cardiac implantable electronic devices (CIED) are mainstay therapy for a variety of patients with bradyarrhythmia as well as those at risk of sudden cardiac death and heart failure. At present, commonly used venous access are axillary, cephalic cutdown, and subclavian puncture. However, there are situations when these approaches cannot be employed because cannulation is not possible due to small size, spasm, absence, or occlusion of the vein. One of the alternative approaches is through an internal or external jugular vein. A jugular vein approach can be also used for upgrading CIED knowing that CIED is not commonly associated with venous occlusion.

CASE REPORT: We present 3 cases which used unusual venous access for placement of CIED using a jugular vein approach.

CONCLUSIONS: Recognizing patients who have difficult venous access for CIED and using alternative approaches, like a jugular vein approach, for device insertion is important to avoid unnecessary medical and technical complications.

Keywords: Cardiac Resynchronization Therapy Devices, Defibrillators, Implantable, Vascular Access Devices

Background

Cardiac implantable electronic devices (CIEDs) are mainstay therapy for a variety of patients with bradyarrhythmia as well as those at risk of sudden cardiac death and heart failure. Although technical progress has been made allowing some devices to be implanted without dwelling intravascular leads (subcutaneous defibrillator and leadless single chamber pacemaker), the majority of CIEDs will still require vascular access for lead placement. About one million patients worldwide receive CIEDs annually [1]. Before 1979, cephalic cutdown was usually used for transvenous pacing [2]. The dexterity of an operator to obtain the cephalic vein access was essential for this procedure because it demanded deep dissection. At present, commonly used venous access approaches are axillary, cephalic cutdown, and subclavian puncture [2,3]. However, there are situations when these approaches cannot be employed because cannulation is not possible due to small size, spasm, absence or occlusion of the vein. These can be particularly challenging in patients with prior device implantation with a crowded or occluded vein, and patients with prior vein manipulation, vein access, or stenting. Other veins can be used for lead placement, but they pose unique challenges. Alternative approaches in such situations include dilatation of a chronically occluded veins, venoplasty, femoral vein, or surgical approach. Here we are presenting 3 cases where we used unusual venous access for placement of CIED, using a jugular vein approach.

Case Reports

CASE 1:

An 80-year-old male patient with a past medical history of chronic heart failure with reduced ejection fraction, an implantable dual chamber cardioverter defibrillator (ICD), hypertension, and chronic kidney disease was admitted because of an episode of appropriate ICD shock. The ICD was implanted in 2007. Battery depletion was evident on the interrogation as well as markedly elevated right ventricular pacing threshold. During his hospitalization, echocardiogram revealed an ejection fraction of 25% and left bundle branch block (LBBB) with QRS duration of 152 ms. The decision was made to proceed with an upgrade to the biventricular ICD and RV lead revision.

Venography of the right and left upper extremities was performed, which revealed bilateral total occlusion at the level of the subclavian veins (Figure 1A). Right internal jugular vein access was considered; however, this access failed even with the use of ultrasonography guidance. External jugular vein access was contemplated as a last resort. The right external jugular vein was accessed with Seldinger technique and by using ultrasound guidance; and new right ventricular (RV) and the coronary sinus (CS) leads were inserted successfully. The leads were tunneled to the previous left subcutaneous pocket (Figure 1B). The old ICD device was explanted, and a new biventricular ICD device was implanted. The procedure was performed successfully without any complication.

CASE 2:

A 67-year-old female patient with a past medical history of chronic heart failure with reduced ejection fraction, with implanted ICD (Figure 2A), permanent atrial fibrillation, end-stage renal disease on hemodialysis, and type 2 diabetes mellitus was admitted due to acute exacerbation of heart failure. Electrocardiogram (ECG) showed LBBB. Transthoracic echo-cardiogram revealed the ejection fraction of 30–35%; therefore, the decision was made to proceed with upgrade to resynchronization system.

The right internal jugular vein was used because of the occlusion of right and left subclavian veins. Using posterior approach and Seldinger technique under ultrasound guidance, the right internal jugular vein was successfully cannulated. A CS lead was inserted with satisfactory sensing and pacing threshold, and the parameters were confirmed. Subsequently, the CS lead was tunneled to the left subcutaneous pocket. A new biventricular (BIV)-ICD device was implanted. The patient tolerated the procedure very well and recovery was uneventful (Figure 2B, 2C).

CASE 3:

A 48-year-old male patient with a past medical history of chronic heart failure with reduced ejection fraction, with implanted single chamber ICD, stroke with residual right hemiparesis, and multiple gunshot wound that led to exploratory laparotomy with partial colon resection was admitted with acute exacerbation of congestive heart failure. Medical treatment was optimized; however, there was no improvement in his condition. Given the presence of LBBB and ejection fraction of 10% on echocardiography, a decision was made to proceed with an upgrade to biventricular defibrillator.

Right and left upper extremity venography was performed, which revealed a severe subclavian stenosis and a patent cephalic vein (Figure 3A). Left cephalic vein access was obtained with a cutdown technique. However, the glide wire did not advance through the cephalic vein, and repeat venography revealed total occlusion of the subclavian veins (Figure 3B). Using ultrasonography guidance, the right internal jugular vein was utilized for lead placement. The vessel was accessed with a single puncture. Right atrial and CS leads were inserted and tunneled to the right infraclavicular pocket. A biventricular ICD device was attached to the leads and implanted (Figure 3C). The patient tolerated the procedure well and no complications were encountered.

Discussion

We have presented a series of cases to substantiate the viability of the external and internal jugular veins in biventricular ICD implantation. Venous occlusion is common in patients with implanted pacing devices particularly those with multiple comorbidities. The incidence of asymptomatic high-grade stenosis-occlusion is 20% to 30% and of symptomatic cases is 1% to 3% [4]. All of our patients had right and left subclavian occlusions. The jugular veins are captivating alternative access sites. In an external and internal jugular approach, incisions above the clavicle and between posterior border of the sternocleidomastoid muscle and anterior trapezius muscle are necessary. Seldinger technique is usually used for the lead insertion. The right external jugular vein is commonly the preferred access because it is less tortuous. Its size should easily accommodate contemporaneous pacing leads [5].

During a jugular venous approach, manipulation of the guide sheath, diagnostic catheter, occlusion balloon or pacing wire may cause the coronary sinus to be dissected or perforated, which may result in minor asymptomatic staining of the coronary sinus and in rare cases, may result in pericardial effusions and tamponade [6]. In the case of an external jugular vein, like the cephalic vein, it has no significant complications as bleeding, air embolism, and pneumothorax [6,7]. However, there is a dislodgment of the endocardial electrode with the use of external jugular vein, which would be eliminated using the internal jugular vein. The internal jugular vein also has the advantages of being readily accessible, passing the catheter electrode easily through the vein, and decreasing motion on the catheter electrode [8].

CIED implantation is associated with an increased incidence of venous occlusion around the site of intervention. The risk varies between 9–26% of the cases, with either partial or complete occlusion, and it is higher in patients with chronic kidney disease and end stage renal disease who are on hemodialysis [9–11]. Therefore, the need for different approaches in such cases is imminent. There are multiple alternative approaches in cases with total axillary and subclavian veins occlusion. McCotter et al. [12] described an alternative approach through advancing a guide wire across the occluded segment then dilatation or venoplasty performed. Alternatively, inside-out central venous access can be obtained via femoral approach. Through femoral vein, a catheter can be advanced crossing right atrial cavity to reach the proximal point of the occluded vein. Then, the occluded segment is accessed with a guided needle which runs through tissue planes inside or outside the vessel. A guide wire needle is advanced until it penetrates the skin at subclavian area. Using the guide wire, a rigid dilator is advanced through the occluded vein segment. Then the leads are advanced through the created tunnel [13]. Gonna et al. [14] described another approach for left ventricular lead placement percutaneously using femoral access, by pulling the leads through until it reaches the pectoral area. Ultrasound-guided vascular access is increasingly being used and reported, with lower risk of complications, lead damage, and minimizing the need for radiation and ipsilateral venous access [15]. Recently, using a leadless intracardiac pacing system was shown to be safe and effective [16,17]. However, it cannot be used for cardiac resynchronization therapy. On the other hand, surgical placement of the leads is an alternative, however, it is more invasive.

The disadvantage of using jugular veins is the increased lead mobility and the exposure to mechanical trauma. Moreover, this approach requires lead tunneling, including tunneling above the clavicle which exposes the leads to not only repetitive flexion but also possible external compression. Nevertheless, in cases where standard access sites are not possible, the jugular veins should be considered.

Conclusions

Recognizing patients with difficult venous access for CIED and using alternative approaches, like a jugular vein approach, for device insertion is important to avoid unnecessary medical and technical complications.

References:

1.. Roger VL, Go AS, Lloyd-Jones DM, Heart disease and stroke statistics – 2011 update: A report from the American Heart Association: Circulation, 2011; 123(4); e18-209, pmid: 21160056

2.. Hayes DL, Asirvatham SJ, Friedman PA: Cardiac pacing, defibrillation and resynchronization – a clinical approach; 2103, West Sussex, UK, Wiley-Blackwell

3.. Budzikowski AS, Levine E, Cephalic vein cutdown. [online] Clinical Procedures. Drugs & Diseases: Medscape, 2017 (Updated June 2019); Available from:

4.. Lickfett L, Bitzen A, Arepally A, Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement: Europace, 2004; 6(1); 25-31, pmid: 14697723

5.. Brieda M, De Mattia L, Dametto E, Placement of a coronary sinus pacing lead from a sub-occluded left subclavian vein using a collateral vein to the right subclavian vein: Indian Pacing Electrophysiol J, 2011; 11(6); 176-79, pmid: 22090732

6.. Ellery SM, Paul VE, Complications of biventricular pacing: Eur Heart J Suppl, 2004; 6(SupplD); D117-21

7.. Furman S, Venous cutdown for pacemaker implantation: Ann Thorac Surg, 1986; 41(4); 438-39, pmid: 3963922

8.. Leininger BJ, Neville WE, Use of the internal jugular vein for implantations of permanent transvenous pacemakers. Experiences with 22 patients: Ann Thorac Surg, 1968; 5(1); 61-65, pmid: 5634783

9.. Haghjoo M, Nikoo MH, Fazelifar AF, Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: A contrast venographic study on 100 patients admitted for generator: Europace, 2007; 9(5); 328-32, pmid: 17369270

10.. Teruya TH, Abou-Zamzam AM, Limm W, Symptomatic subclavian vein stenosis and occlusion in hemodialysis patients with transvenous pacemakers: Ann Vasc Surg, 2003; 17; 526-29, pmid: 12958674

11.. Kusztal M, Nowak K, Cardiac implantable electronic device and vascular access: Strategies to overcome problems: J Vasc Access, 2018; 19(6); 521-27, pmid: 29552930

12.. McCotter CJ, Angle JF, Prudente LA, Placement of transvenous pacemaker and ICD leads across total chronic occlusions: Pacing Clin Electrophysiol, 2005; 28(9); 921-25, pmid: 16176530

13.. Elayi CS, Allen CL, Leung S, Inside-out access: A new method of lead placement for patients with central venous occlusions: Heart Rhythm, 2011; 8(6); 851-57, pmid: 21237290

14.. Gonna H, Domenichini G, Zuberi Z, Femoral implantation and pull through as an adjunct to traditional methods in cardiac resynchronization therapy: Heart Rhythm, 2016; 13(6); 1260-65, pmid: 26820509

15.. Seto AH, Jolly A, Salcedo J, Ultrasound-guided venous access for pacemakers and defibrillators: J Cardiovasc Electrophysiol, 2012; 24(3); 370-74, pmid: 23131025

16.. Reddy VY, Exner DV, Cantillon DJ, Percutaneous implantation of an entirely intracardiac leadless pacemaker: N Engl J Med, 2015; 373(12); 1125-35, pmid: 26321198

17.. Reynolds D, Duray GZ, Omar R, Micra transcatheter pacing study group A leadless intracardiac transcatheter pacing system: N Engl J Med, 2016; 374; 533-41, pmid: 26551877

In Press

Case report  China

Thrombolytic Therapy After Return of Spontaneous Circulation in Patients With STEMI From Medically Underdev...

Am J Case Rep In Press; DOI: 10.12659/AJCR.949976  

Case report  Greece

Multilevel Laminectomy for Lumbar Spinal Stenosis With Low Back Pain in Achondroplasia: A Case Report

Am J Case Rep In Press; DOI: 10.12659/AJCR.950290  

Case report  Italy

Fractional CO₂ Laser (SCAR3 Scanner) for a Hypertrophic Retracting Cleft Lip Scar: A Case Report

Am J Case Rep In Press; DOI: 10.12659/AJCR.950607  

Case report  Saudi Arabia

Postoperative Corneal Dellen Following PreserFlo MicroShunt: A Case Report

Am J Case Rep In Press; DOI: 10.12659/AJCR.950985  

Most Viewed Current Articles

07 Dec 2021 : Case report  USA 17,691,734

Edwardsiella tarda: A Classic Presentation of a Rare Fatal Infection, with Possible New Background Risk Fac...

DOI :10.12659/AJCR.934347

Am J Case Rep 2021; 22:e934347

06 Dec 2021 : Case report  Brazil 164,491

Lipedema Can Be Treated Non-Surgically: A Report of 5 Cases

DOI :10.12659/AJCR.934406

Am J Case Rep 2021; 22:e934406

21 Jun 2024 : Case report  China (mainland) 113,090

Intracranial Parasitic Fetus in a Living Infant: A Case Study with Surgical Intervention and Prognosis Anal...

DOI :10.12659/AJCR.944371

Am J Case Rep 2024; 25:e944371

0:00

07 Mar 2024 : Case report  USA 59,175

Neurocysticercosis Presenting as Migraine in the United States

DOI :10.12659/AJCR.943133

Am J Case Rep 2024; 25:e943133

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

American Journal of Case Reports eISSN: 1941-5923
American Journal of Case Reports eISSN: 1941-5923