Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

30 October 2013 : Original article  

Diagnostic quality of CT pulmonary angiography in pulmonary thromboembolism: A comparison of three different kV values

Ömer YılmazABDEF, Esma Dilek ÜstünBDE, Mustafa KayanAB, Fatmanur KayanF, Aykut Recep AktaşB, Elif Nisa ÜnlüCDE, Bumin DeğirmenciFG, Meltem ÇetinFG

DOI: 10.12659/MSM.889578

Med Sci Monit 2013; 19:908-915

Abstract

BACKGROUND: Our purpose was to evaluate the effectiveness of different kilovolt (kV) uses in computed tomography pulmonary angiography (CTPA) in the diagnosis of pulmonary thromboembolism (PTE). We also aimed to establish the optimal kV value and investigate the possibility of obtaining appropriate imaging quality with minimal radiation dose.

MATERIAL AND METHODS: We compared 120, 100, and 80 kV CTPA for 90 patients in whom PTE was clinically considered. The examinations were carried out using a 128 multislice CT device (Definition AS, Siemens Medical Solutions, Forchheim, Germany). Each kV value was used on 30 patients in 3 groups. Patients in all groups were compared with respect to the mean radiation dose they received, pulmonary arterial attenuation values, image quality, and motion artefacts.

RESULTS: With respect to pulmonary arterial attenuation values, imaging with 80 kV yielded significantly higher values (p<0.05). However, no difference was found between 120 kV, 100 kV, and 80 kV with respect to image quality. Similarly, no significant difference was detected between the groups with respect to pulmonary artery contrasting and motion artefacts. Statistically significant differences were present in DLP values and effective dose among all 3 groups (p<0.001).

CONCLUSIONS: Using 80 kV as the low value in CTPA imaging for patients pre-diagnosed with PTE will increase the density of pulmonary arteries and decrease the amount of radiation received.

Keywords: Angiography - methods, Analysis of Variance, Image Processing, Computer-Assisted - methods, Prospective Studies, Pulmonary Embolism - diagnosis, Radiation Dosage, Tomography, X-Ray Computed - methods

Add Comment 0 Comments

Editorial

01 April 2024 : Editorial  

Editorial: Forty Years of Waiting for Prevention and Cure of HIV Infection – Ongoing Challenges and Hopes for Vaccine Development and Overcoming Antiretroviral Drug Resistance

Dinah V. Parums

DOI: 10.12659/MSM.944600

Med Sci Monit 2024; 30:e944600

0:00

In Press

05 Mar 2024 : Clinical Research  

Muscular Function Recovery from General Anesthesia in 132 Patients Undergoing Surgery with Acceleromyograph...

Med Sci Monit In Press; DOI: 10.12659/MSM.942780  

05 Mar 2024 : Clinical Research  

Effects of Thermal Insulation on Recovery and Comfort of Patients Undergoing Holmium Laser Lithotripsy

Med Sci Monit In Press; DOI: 10.12659/MSM.942836  

05 Mar 2024 : Clinical Research  

Role of Critical Shoulder Angle in Degenerative Type Rotator Cuff Tears: A Turkish Cohort Study

Med Sci Monit In Press; DOI: 10.12659/MSM.943703  

06 Mar 2024 : Clinical Research  

Comparison of Outcomes between Single-Level and Double-Level Corpectomy in Thoracolumbar Reconstruction: A ...

Med Sci Monit In Press; DOI: 10.12659/MSM.943797  

Most Viewed Current Articles

17 Jan 2024 : Review article  

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

14 Dec 2022 : Clinical Research  

Prevalence and Variability of Allergen-Specific Immunoglobulin E in Patients with Elevated Tryptase Levels

DOI :10.12659/MSM.937990

Med Sci Monit 2022; 28:e937990

0:00

16 May 2023 : Clinical Research  

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Jan 2022 : Editorial  

Editorial: Current Status of Oral Antiviral Drug Treatments for SARS-CoV-2 Infection in Non-Hospitalized Pa...

DOI :10.12659/MSM.935952

Med Sci Monit 2022; 28:e935952

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750